TOXALERTINTERNATIONAL,INC.P.O.BOX159,MOUND,MINNESOTA55364*(952)472‐4541*FAX(952)472‐4960
Visitourwebsiteatwww.toxalert.com
Construction:
Dimensions: 7.0 x 3.6 x 4.0 in. (H x W x D)
(17.8 x 9.1 x 11.2 cm.)
TOX45-25/26 8.4 x 4.4 x 3.9 in (H x W x D)
(21.3 x 11.2 x 9.9 cm.)
Weight: 2.2 lb. (1.0 Kg) Al
4.6 lb. (2.1 Kg) SS
TOX45-25/26 3.0 lb. (1.3 Kg) Al
5.0 lb. (2.3 Kg) SS
Enclosure: Nema 4X, Nema 7
Aluminum or Stainless Steel
Limited warranty: 1 Year
2-Wire Toxic Gas Sensor Module Model TOX45-XX
Specifications:
Specifications subject to change without notice
Ordering Information:
Model - Gas - Enclosure Accessories
TOX45 Series -03 = O
2
- A1 (Aluminum) 4511-00 Rainshield
-04 = CO - S1 (Stainless Steel) 4511-02 Rainshield with calibration port
-05 = H
2
S 4558-01 Calibration Adaptor, Standard
-06 = Cl
2
4558-51 Calibration/configuration magnetic tool
-08 = CIO
2
4560-00 Calibration gas delivery fitting
-10 = SO
2
-12 = NO
2
-25 = NH
3
-26 = HF
Example: TOX45-04-A1=CO Sensor with aluminum enclosure
Performance Max. Gas Range (1 ) Resolution Response Time (2) Sensor Life
TOX45 -03 O
2
0 - 25 % Vol 0 .2 % Vol. < 1 0 Seconds 20 Months
TOX45 -04 CO
0 – 1000 PPM 0 . 5 PPM <25 Seconds 2 Years
TOX45 -05 H
2
S
0 - 100 PPM 0 . 1 PPM <30 Seconds 2 Years
TOX45-06 Cl
2
0 - 10 PPM 0 . 1 PPM <60 Seconds 2 Years
TOX45-08 ClO
2
0 - 3 PPM 0 . 1 PPM <60 Seconds 2 Years
TOX45 -1 0 SO
2
0 - 100 PPM 0 . 5 PPM <20 Seconds 2 Years
TOX45-1 2 N O
2
0 - 20 PPM 0 .2 PPM <35 Seconds 2 Years
TOX45 - 25 NH
3
0 - 100 PPM 1 .0 PPM <30 Seconds (3)
TOX45-26 HF
0 - 10 PPM 1 .0 PPM <90 Seconds (3)
(1) Other ranges available
(2) To 90% range
(3) Ammonia and HF sensor
Requires electrolyte
recharge up to one (1)
Year “intervals”.
Output:
Display: LCD,2‐line,16‐characters
SignalOutput: 2‐wiresensorpoweredanalog4‐20mA
(Trouble:3.6mA)
LoopResistance: 800ohm
ElectricalData:
PowerConsumption: 0.2watts
ConnectionType: 2‐wire,loop‐powered
InputVoltage: 24VDCnominal:14‐30VDC
RFI/EMIProtection: EN50081‐2,EN50082‐2
OperatingRange:
AmbientTempRange:
Standard: ‐4°to122°F(‐20°to50°C)
TOX45‐25/26
14°to113°F(‐10°to45°C)
ExtendedTemp: Sensorand4‐20mAwillcontinuetooperate
to‐40°F(‐40°C)buttheLCDdisplaywilldecay
overtimeifexposedtotemperaturesbelow
‐4°F(‐20°C)forsignificanttime(notforTOX45‐25)
StorageTemp: ‐4°Fto
122°F(‐20°to50°C)
RelativeHumidity:
Standard: 15‐90%
TOX45‐25NH
3
20‐90%
TOX45-xx